Anti-Flood Vent Covers

M3AFVC

A specialist solution to prevent flood water accessing openings required for venting appliances or other openings allowing air to vent through building framework.

Anti-Flood Vent Covers

M3AFVC

A specialist solution to prevent flood water accessing openings required for venting appliances or other openings allowing air to vent through building framework.

Anti-Flood Vent Covers

All properties have openings for venting appliances or for allowing air to vent through the building framework. Quite often these are irregular shapes or are located in awkward positions, so specialist solutions are needed to prevent flood water accessing the opening and flooding the building. Under these circumstances bespoke covers can be designed and installed over the opening to prevent flooding events.

Manufactured from high grade aluminium (5052), these vent seals can be fully closed or adapted with openings above the flood levels and as snorkel vents for use with existing passive flood prevention products such as the Anti-flood Airbrick. Either passive or deployable and powder coated to any colour, Vent covers offer a 100% assured flood protection to any building vent.

  • Manufactured any shape or size
  • High grade 5052 aluminium in any colour
  • Passive or deployable
  • Suitable for use in listed buildings
  • Can be retro fit or used in new build
  • Not suitable for gas appliance vents
Anti-Flood Vent Covers Key Points
  • Manufactured any shape or size
  • High grade 5052 aluminium in any colour
  • Passive or deployable
  • Suitable for use in listed buildings
  • Can be retro fit or used in new build
  • Not suitable for gas appliance vents

Not suitable for Gas Appliance Vents

Quality tested & certified.

Our Anti-Flood Vent Covers have been thoroughly tested and checked, time and again, and proven to meet a recognized industry standard.

Tested & Certified to KM713574

Tested by BSI to the new British Standard BS 851188

Technical Information

Applications
  • Can be fitted to any vent opening except for a gas appliance exhaust
  • Can be manufactured to any size
  • Can be installed in brick, concrete, stone, steel, render finished or hardwood structures across both domestic and commercial properties
  • Can be installed as snorkel vent inside cavities allowing underfloor ventilation above flood levels
Certification
  • Tested to the criteria of PAS 1188-1:2014
  • When used with an airbrick in snorkel configuration, conforms with BS 493:1995 for air flow ventilation
Other Information
  • Can be manufactured to any height, width or depth
  • Utilises M3 Floodtec design patented flood seal
  • Excellent resistance to oxidisation, ultra violet light
  • Temperature range -30°C to 100°C
Components
  • Grade 5052 3mm thick aluminium
  • Powder coat to any RAL colour
  • Rubber Flood seal patent ref 003764778

Anti-Flood Vent Covers: Request a Quotation

If you would like to receive a free quotation, please start a new quotation by clicking the button below.

Your Details

Your Enquiry

Submitting your details lets us know that you are happy to receive communication from us and that you have also read our privacy statement. You can opt out of these communications at any time.

Please tick the above box to enable the form.

BSI Flood Protection Kitemark KM713574
ISO 9001 Quality Management
SSIP
Constructionline
Fensa
Chas Elite
Hereford & Worcestershire Chamber of Commerce
Leaders Council
CPA
Parlimentary Review
Chas
Accoya
Bimstore
Site by Kingsford

Flood Checker